Settings on the Shelly Homepage - Only for Shelly 2 / 2.5

  • Settings on the Shelly Homepage
    Supplements specifically for Shelly 2 / 2.5

    Only for Shelly 2 / 2.5



    Homepage







    Safety





    MAX POWER PROTECTION


    Custom Max Power Protection - Der Shelly 2.5 schaltet bei vordefiniertem maximalen Leistungswert AUS. Bereich: 1-2300W.

    Nach Eingabe des gewünschten Leistungswertes mit SAVE bestätigen.


    in Relay Mode: Safety and Actions are not included in the main overview!

    Settings only possible after selecting the channel (channel 1 or 2)! (see picture "Safety")




    Settings







    DEVICE TYPE

    Selection: Relay- or Roller Shutter mode





    Relay - Configure Shelly Device as a 2-circuit relay, two separately switchable relay outputs O1 / O2

    Roller Shutter - Configure Shelly Device in Roller Shutter-Mode, software channel lock




    POWER ON PARAMETERS

    This sets the Devices‘ default state when powered from the power grid. As Initial Inclusion; after a power failure.







    OPEN / CLOSE WORKING TIME





    Time setting in seconds for automatic STOP-function when opening / closing the shutter.

    After typing the desired time, press Save.




    INPUT BUTTON MODE

    Selection of the button or switch mode





    One button - each press changes the action (UP / STOP / DOWN / STOP / ...)

    Open & Close Buttons - two separately buttons / switches each direction (UP / DOWN)




    BUTTON TYPE

    Selection of the button or switch type





    Reverse switch - Reversing the switch UP / DOWN position.


    Detached Switch - Detached mode is used when you don’t want the physical switch that is wired to the Shelly to directly control the electrical consumer, but instead you’ll use the “action” menu, or MQTT, API, ect. to control some sophisticated action.

    You can also use detached mode to temporarily disable the physical switch.




    REVERSE CONTROLS





    Reverse inputs - In the case of a hard-to-reach switch installation, this option can be activated.




    POSITIONING CONTROLS





    Enable positioning controls - Disable or Enable positioning controls

    CALIBRATE - Start the Shutter Calibration


    More information: calibration Shelly 2 / 2.5 - Roller shutter - mode

Share